Material:
The indoor multi-core distribution cable structure is based on tight-buffered optical fiber as the basic unit. The multi-core bundled cable is used as a subunit and is twisted into a circular shape with FRP and then extruded into a PVC (or LSZH) sheath to form a cable. Between the core and the sheath, a dry water blocking material is placed.
Fiber Count | Dimension (MM) | Weight (kg/km) | Tensile (N) LongTerm/Short Term | Crush(N/100mm) LongTerm/Short Term | Min.Bend Radius(mm) Dynamic / Static | Temperature (°C) | |||
4 | 5.0 | 19 | 130 | 440 | 200 | 1000 | 20D | 10D | -20~+70 |
6 | 5.2 | 23 | 130 | 440 | 200 | 1000 | 20D | 10D | -20~+70 |
8 | 5.5 | 26 | 130 | 440 | 200 | 1000 | 20D | 10D | -20~+70 |
12 | 6.5 | 36.5 | 200 | 660 | 200 | 1000 | 20D | 10D | -20~+70 |
16 | 7.5 | 44.5 | 200 | 660 | 200 | 1000 | 20D | 10D | -20~+70 |
24 | 8.2 | 54.5 | 200 | 660 | 200 | 1000 | 20D | 10D | -20~+70 |
36 | 9.2 | 72.0 | 200 | 660 | 200 | 1000 | 20D | 10D | -20~+70 |
48 | 10.5 | 90.0 | 200 | 660 | 200 | 1000 | 20D | 10D | -20~+70 |
Note: 1. All the values in the table, which are for reference only, are subject to change without notice; 2. The cable dimension and weight are in accordance with tight-buffered fiber withφ0.9mm outer diameter; 3. Dis outer diameter of the round cable; 4. The minimum bend radius (static) is 5D when G.657 fiber is used. |